Maintenance
12. Secure the casing (100) to the workbench with the suction flange facing downwards.
1. Adapter-to-case hex screw (370)
2. Frame adapter (108)
3. Backplate-to-case gasket (351)
4. Casing (100)
13. Insert the casing gasket (351) into the casing.
14. Insert the pre-assembled unit into the casing so that the crane hook of the adapter (108)
faces the center of the discharge nozzle.
15. Secure the adapter to the casing using hex screws (370) to the appropriate torque value.
See
70
Model 3296 EZMAG Installation, Operation, and Maintenance Manual
Advertising