Installation

Check

Explanation/comment

Checked

Check that the piping is level or

slopes downward from the liquid
source.
Make sure that no part of the

suction piping extends below the
suction flange of the pump.
Make sure that the size of the

entrance from the supply is one or
two sizes larger than the suction
pipe.
Make sure that the suction piping

This prevents air from entering the

is adequately submerged below

pump through a suction vortex.

the surface of the liquid source.

Correct

Incorrect

The correct distance between the inlet flange of the
pump and the closest elbow is at least two pipe
diameters.

1.

Enough distance to prevent cavitation

2.

Eccentric reducer with a level top

Example: Suction piping equipment

Correct

Incorrect

1.

Suction pipe sloping upwards from liquid source 1.

Air pocket, because the eccentric reducer is not

2.

Long-radius elbow

used and because the suction piping does not

3.

Strainer

slope gradually upward from the liquid source

4.

Foot valve

5.

Eccentric reducer with a level top