Seal the shaft with a dynamic seal

1. Place the backplate (444) with the flat side down on the bench.

444

184

262

264

107

355

106

265

2. Place the repeller (262) in the backplate (444) with the sleeve side up.
3. Place a Teflon gasket (264) on the backplate (444) and align the holes in the gasket with the holes in

the backplate.

4. Place a stuffing-box cover (184) on the backplate (444) and align the holes in the gasket with the holes

in the backplate.

5. Install four socket-head capscrews (265) and tighten them securely.
6. Install a new sealing element into the gland.
7. Install a gasket (360Q) and gland (107) on the stuffing-box cover (184).
8. Install the nuts (355).
9. Install a dynamic-seal assembly and nuts (370H).

370H

10. Check the stuffing-box-cover runout and rotate the indicator through 360 degrees.

An indicator reading that is greater than 0.005 in. (0.013 mm) indicates a problem.