Goulds Pumps LF 3196 i-FRAME - IOM User Manual
Page 74
184
355
250
370H
4. Remove the shaft sleeve (126) if it is used.
The mechanical seal is attached to the sleeve.
NOTICE: Be careful with the stationary portion of the mechanical seal that is either clamped
between the backplate and the gland or seated in the seal-chamber bore. Failure to do so may result in
equipment damage.
5. Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off the
sleeve.
Refer to the mechanical-seal instructions for more information.
6. Remove the gland (250), the stationary portion of the seal, and the O-ring (360Q).
126
383
360Q
383
250
Remove the stuffing-box cover (3196, CV 3196, HT 3196, LF 3196, 3796)
1. Remove the gland nuts (355) and the gland (107).
2. Remove the stuffing-box-cover nuts (370H).
3. Remove the stuffing-box cover (184).
Maintenance
72
Model LF 3196 i-FRAME Installation, Operation, and Maintenance Manual