Part description LF 3196

3196

3796

HT 3196

CV 3196

LF 3196

3198

NM 3196

Casing

Impeller

Cover

Power end

Figure 6: LF 3196 part description

This table describes the pump casing parts.

Table 3: Casing

Part

Description

Discharge

Top-centerline

Casing ventilation

Self venting

Gasket

Fully confined

Mounting method

Integral foot support for maximum resistance to misalignment and distortion due

to piping loads.

Standard flange

• ANSI class 150 raised-face serrated flanges are standard on 4 in., 8 in., and 10

in. sizes

• ANSI class 300 raised face serrated flange is standard on the 13 in. size

Optional flanges

ANSI class 300 raised-face serrated flange is optional on 4 in., 8 in., and 10 in.

sizes.

Impeller

The impeller is

• fully open with radial vanes and balance holes
• screwed onto the shaft

The threads are sealed from the pumped liquid by a Teflon O-ring.

Product Description

Model LF 3196 i-FRAME Installation, Operation, and Maintenance Manual