Goulds Pumps LF 3196 i-FRAME - IOM User Manual
Page 79
Advertising
4. Remove the jack screws (370D) with the nuts (423).
134
236A
496
253B
370D
423
5. Remove the bearing housing O-ring (496).
6. Remove the clamp ring screws (236A) and separate the clamp ring (253B) from the bearing housing
(134).
You must remove the bearings before you can remove the clamp ring from the shaft.
7. Remove the bearing housing (134) and the bearings (112A and 168A) from the shaft (122).
250
184
355
370H
8. Remove the inboard bearing (168A).
122
168A
253B
382
136
112A
9. Remove the bearing locknut (136) and bearing lockwasher (382).
10. Remove the outboard bearings (112A).
Maintenance
Model LF 3196 i-FRAME Installation, Operation, and Maintenance Manual
77