Remove the dynamic seal, Emove the dynamic seal – Goulds Pumps LF 3196 i-FRAME - IOM User Manual
Page 75
Advertising
107
184
370H
355
184
370H
355
107
4. Remove the shaft sleeve (126).
105
184
106
5. Remove the packing (106) and lantern ring (105) from the stuffing-box cover (184).
A lantern ring does not come with self-lubricating graphite packing.
105
184
106
Remove the dynamic seal
1. Remove the stud nuts (370H).
2. Remove the dynamic-seal assembly.