Seal-chamber cover removal – Goulds Pumps LF 3196 i-FRAME - IOM User Manual

Page 73

Advertising
background image

Shaft Wrench

101

4. Repeat step 3 until the impeller becomes loose.
5. Remove and discard the impeller O-ring (412A).

You will insert a new O-ring during reassembly.

412A

Figure 16: O-ring for model LF 3196

If the impeller cannot be removed by the previous methods, cut the shaft between the gland and the
frame, remove the impeller, stuffing-box cover, gland, sleeve, and shaft end as a unit. Do not apply heat.

Seal-chamber cover removal

Seal-chamber removal procedures

Choose from one of these procedures to remove the seal-chamber cover.

Table 10: Procedures for seal-chamber cover removal by model

Model

Procedure

3196, CV 3196, HT 3196, LF 3196, 3796

Remove the seal-chamber cover.

NM 3196, 3198

Remove the seal-chamber cover and/or backplate.

Remove the seal-chamber cover (3196, CV 3196, HT 3196, LF 3196, 3796)

1. Remove the gland stud nuts (355).
2. Remove the seal-chamber stud nuts (370H).
3. Remove the seal chamber (184).

Maintenance

Model LF 3196 i-FRAME Installation, Operation, and Maintenance Manual

71