Lubrication conversion, Frame lubrication conversion – Goulds Pumps LF 3196 i-FRAME - IOM User Manual

Page 117

Advertising
background image

Lubrication conversion

Frame lubrication conversion

NOTICE:

• Never mix greases of different consistencies (NLGI 1 or 3 with NLGI 2) or with different thickeners.

For example, never mix a lithium-based grease with a polyurea-based grease. Doing so may result in
decreased performance.

• Remove the bearings and old grease if you need to change the grease type or consistency. Failure to

do so may result in equipment damage or decreased performance.

Use a grease that is suitable for high temperatures when you have frame pumpage temperatures greater
than 350°F (177°C). Ensure that mineral-oil greases have oxidation stabilizers and a consistency of NLGI
3.
Most pumps use Sunoco 2EP grease. High temperature units with a pumpage temperature greater than

350° F (177°C) use Mobil SCH32.
This table shows which brand of grease to use when lubricating the pump.

Table 23: Lubricating-grease requirements

Pumpage temperature less than

350°F (177°C)

Pumpage temperature greater

than 350°F (177°C)

NGLI consistency

2

3

Mobil

Mobilux EP2

SCH32

Exxon

Unirex N2

Unirex N3

Sunoco

Mutipurpose 2EP

N/A

SKF

LGMT 2

LGMT 3

Convert from greased-for-life or regreaseable to oil-lubricated bearings

1. Remove the plug from the oil-return slot in the frame located under the radial bearing. Use this table

as a guide.

Pump model

Action

STi

Remove the epoxy from the return slot.

MTi, LTi

Remove the set screw installed in the oil-return hole.

2. Remove the plug from the oil-return hole in the bearing housing (134).

NOTICE: For the LTi, the bearing housing (134) and clamp ring (253B) require replacement. Failure
to do so may result in decreased performance.

3. Replace both bearings with unshielded, oil-lubricated bearings.

Table 24: Bearing types

Frame

Inboard bearing

Outboard bearing

Double row

Duplex

STi

6207

3306

7306

MTi

6309

3309

7309

LTi

6311

Not applicable

7310

4. Remove the grease fittings (193) to prevent accidental greasing.

Two plugs (408H) are required to replace the two grease fittings.

Maintenance

Model LF 3196 i-FRAME Installation, Operation, and Maintenance Manual

115