Disassemble the bearing frame

1. Remove these plugs from the bearing frame (228A).

• oil-fill plug (113A)
• oil-drain plug (408A)
• sight-oiler plug (408J)
• four oil mist/grease connection plugs (408H)
• oil-cooler inlet and outlet plugs (408L and 408M) or oil cooler

2. For the MTi and LTi models, remove the bearing frame foot-to-frame bolts (370F) and the frame foot

(241).

319

408N

408A

241

370F

408N

408W

372T

113A

408W

408M

761B

Guidelines for i-ALERT

Condition Monitor disposal

Precautions

WARNING:

• Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these

temperatures could result in death or serious injury.

• Never dispose of the condition monitor in a fire. This could result in death or serious injury.

Guidelines

The battery contained in the condition monitor does not contain enough lithium to qualify as reactive
hazardous waste. Use these guidelines when disposing of the condition monitor.

• The condition monitor is safe for disposal in the normal municipal waste stream.
• Adhere to local laws when you dispose of the condition monitor.