Heat controller oem price list, Hww model structure, Basic unit description – Comfort-Aire HWW120 User Manual

Page 3

Advertising
background image

2

Heat Controller, Inc.

WATER-TO-WATER (HWW) SERIES

Installation & Operation

Page 21

7 May, 2009

HEAT CONTROLLER OEM PRICE LIST

HWW HIGH EFFICIENCY Water-to-Water HFC-410a Heat Pumps

The basic unit price includes sealed heat pump refrigerant circuit.

Cabinet - Heavy gauge galvanized steel with black polyester powder

coat paint – multiple removable panels for service access – stainless
steel front access panel(s) – interior surfaces lined with ½ inch dual
density acoustic type glass  ber insulation – IPT water connections –
high and low voltage knockouts.

Controls - Solid state control system with seven standard safeties

including anti-short cycle, over voltage, under voltage, high refrigerant
pressure, loss of refrigerant charge, low source water temperature,
low load water temperature – run and fault lights on cabinet exterior –
alarm contact for remote monitoring of fault condition ( eld selectable
for dry contact or 24vac).

Refrigerant Circuit - Compressor(s) – coaxial source and load heat

exchangers – revering valve(s) –  lter driers(s) – thermal expansion
valve(s) – high pressure and loss of charge switches – high and low
side Schrader ports for service – non-ozone depleting HFC-410a
refrigerant.

Compressor(s) - High ef ciency scroll compressor - internally sprung

and externally isolated using dual vibration isolation system for
quiet operation. Mounting system includes rubber grommet mounts
between the compressor and a mounting tray then another set of
rubber mounts between the mounting tray and unit base pan.

Reversing Valve - 4-way pilot operated, solenoid activated in cooling

mode.

Safety Agency Listing - Product is ETL Listed.

Application - May be applied in water loop heat pump, ground water

heat pump, and ground loop heat pump applications.

Entering Water Temperature Range: 20 - 110°F (-6.7 - 43.3°C)
Sizes 036, 060 & 120

HWW Model Structure

Basic Unit Description:

H W W

A

0 3 6

C

1

1 0 C F C

1 2

3

4 5 6

7

8

9

10

11

12

13

14

HW = HEAT CONTROLLER SERIES HIGH EFFICIENCY

MODEL TYPE

W = WATER TO WATER

CONFIGURATION

UNIT SIZE

036 - 1,3,4

060 - 1,3,4,5

120 - 1,3,4,5

REVISION LEVEL

A = CURRENT

VOLTAGE

CONTROLS

0 = RESIDENTIAL ( 208-230/60/1 ONLY)

CABINET INSULATION

HOT WATER GENERATOR OPTIONS

C = Copper

SOURCE WATER COIL OPTIONS

N = Cupro-Nickel

C = Copper

LOAD WATER COIL OPTIONS

N = Cupro-Nickel

0 = NONE

1 = HWG w/INTERNAL PUMP (RESIDENTIAL)

F = FRONT

WATER CONNECTION LOCATION

1 = COMMERCIAL EXTENDED RANGE

VOLTAGE

2 = HWG COIL ONLY (COMMERCIAL)

C = CXM (ETL for USA & CANADA)

1 = 208-230/60/1 - 410A

3 = 208-230/60/3 - 410A

4 = 460/60/3 - 410A

5 = 575/60/3 - 410A

}

polyster powder

R-410A

HWW HIGH EFFICIENCY Water-to-Water R-410A Heat Pumps

Cabinet- Heavy gauge galvanized steel with polyester powder

coat paint – multiple removable panels for service access – interior

surfaces lined with 1/2 inch dual density acoustic type glass

fiber insulation – IPT water connections – high and low voltage

knockouts.

A=CURRENT 036

B=CURRENT 060, 120

Advertising