Fitting pneumatic components – Festo Линейные приводы DGO, дюймовые User Manual

Page 24

Advertising
background image

DGO−...−A−B

Festo DGO−...−A−B 0410b English

24

Fitting pneumatic components

Fitting in a vertical or sloping position:

Warning
If there is a pressure failure, the work mass will slide down.
Uncontrolled moving masses can cause injury to people or damage to property
(danger of fingers being squashed).

S Check whether non−return valves (with control) of type HGL−... are required

here. In this way, you can prevent the work mass from sliding down suddenly.
(work mass = slide mass + mass of the work load)

Setting the slide speed:

S

Screw one−way flow control valves of type GRLA−... into the compressed air
ports.

Other accessories with excessive screw depth L will damage the internal slide
of the DGO−...Ă. Fig. 12 shows the maximum screw depth:

DGO−...

16

20

25

32

40

L

max

4.8 mm

8 mm

7 mm

9 mm

10 mm

Fig. 12

:

Maximum screw depth L

max

of the compressed air ports

Controlling the DGO−...:

S

Use 3/2−way valves (in basic position
open) for both compressed air ports.

Fig. 13

Advertising
This manual is related to the following products: