Fitting

Mechanical components

Please note
Certain mechanical loadings of the contrac-
tion membrane may damage the DMSP-... /
MAS-... .
S Ensure that the DMSP-... / MAS-... is

– fitted free of torsional forces.
– not fitted bent (crushed) even when

pressureless (no wrinkles).

Please note
If the thread of the adapter of type
MXAC-... is too long, the connecting thread
of the MAS-10-...-

O will be damaged (no

force limitation).
S Make sure that the thread lengths of the

adapter and the MAS-... (see Fig. 5) are
suited to each other.

S Lubricate the thread of the connecting adapter.

The assembly forces will then be reduced.

S In order to fit the adapter as described in the section “Accessories”, screw it

into the fastening thread

1.

The appropriate tightening torque is specified in the table below.

MAS-... / DMSP-...

10-...

20-...

40-...

Connecting thread

6

– DMSP-...-CM/-RM
– (DMSP-...-AM)

M8
(M16 x 1.5)

M10 x 1.25
(M20 x 1.5)

M16 x 1.5
(M30 x 1.5)

Recommended through-
holes [H12]

8.4 mm
(17 mm)

10.5 mm
(21 mm)

17 mm
(31 mm)

Tightening torque

*)

7...10 Nm
(15...19 Nm)

12...16 Nm
(23...28 Nm)

50...55 Nm
(100...110 Nm)

Fig. 3