11
Eliminating faults
Fault
Possible cause
Remedy
Work load is not lifted
Insufficient operating
pressure
Increase operating pressure to max.
permitted value (see Technical
specifications)
The required force is
not reached
Max. permitted force
exceeded
Use a larger DMSP-... / MAS-...
Clearly audible blowing
(only with MAS-...-K)
Operating pressure too
high
Reduce operating pressure
Loading too high
Reduce load
Heavy leakage
Muscle fibre worn
Replace DMSP-... / MAS-...
DMSP-... / MAS-...
does not achieve the
desired speed
Insufficient air volume
Increase connection cross sections,
switch volumes in series
Mass or counteracting
force too high
Select larger DMSP-... / MAS-...
Fig. 11
12
Technical specifications
DMSP-... / MAS-...
10-...
20-...
40-...
Design
Fibre-reinforced contractible membrane
Mounting position
As desired
Medium
Compressed air lubricated or non-lubricated
(other media on request)
Permitted operating pressure
0...8 bar
0...6 bar