Eliminating faults

Fault

Possible cause

Remedy

Work load is not lifted

Insufficient operating
pressure

Increase operating pressure to max.
permitted value (see Technical
specifications)

The required force is
not reached

Max. permitted force
exceeded

Use a larger DMSP-... / MAS-...

Clearly audible blowing
(only with MAS-...-K)

Operating pressure too
high

Reduce operating pressure

Loading too high

Reduce load

Heavy leakage

Muscle fibre worn

Replace DMSP-... / MAS-...

DMSP-... / MAS-...
does not achieve the
desired speed

Insufficient air volume

Increase connection cross sections,
switch volumes in series

Mass or counteracting
force too high

Select larger DMSP-... / MAS-...

Fig. 11

12

Technical specifications

DMSP-... / MAS-...

10-...

20-...

40-...

Design

Fibre-reinforced contractible membrane

Mounting position

As desired

Medium

Compressed air lubricated or non-lubricated
(other media on request)

Permitted operating pressure

0...8 bar

0...6 bar