B. Parameters and data of the CPX terminal

B−4

Festo P.BE−CPX−SYS−EN en 0902e

B.2

Description of the parameters and data

A distinction is made between the following parameters and
data:

Parameters

Description

System paraĆ
meters

Determine global system functions for the
complete CPX terminal, e.g.:
Ĉ Diagnostic monitoring
Ĉ System start etc.

Module paraĆ
meters

Determine module−specific and channel−speĆ
cific functions for the relevant module, e.g.:
Ĉ Input debounce time
Ĉ Signal extension times etc.

Diagnostic memĆ
ory parameters

Determine the working method of the diagnosĆ
tic memory.

Tab. B/1: CPX parameters

Data

Description

System diagnostic
data

Global information on the system status
(e.g. common diagnostic message)

Module diagnostic
data

Information on fault finding (e.g. error number,
number of the first faulty channel etc.)

Diagnostic memĆ
ory data

Entries in the diagnostic memory (max. 40)

System data

Information on global system settings

Module data

Serial number, revision code and module code
of the modules used

Tab. B/2: CPX data