3 the power supply concept of the cpx terminal, The power supply concept of the cpx terminal – Festo Контроллер позиционирования CPX-CMPX User Manual

Page 37

Advertising
background image

1. Overview of components

1−19

Festo P.BE−CPX−SYS−EN en 0902e

Note
With a combination of connection blocks and interlinking
blocks with metal on plastic or plastic on metal, always use
the appropriate screws for the

interlinking block (see

www.festo.com\catalogue):

Ĉ With plastic interlinking block: thread−cutting screws

Ĉ With metal interlinking blocks: screws with metric thread

1.1.3

The power supply concept of the CPX terminal

The operating and load voltages for the CPX terminal are supĆ
plied via the interlinking blocks (see Tab. 1/5 and Tab. 1/6).
These conduct the operating and load voltages to the neighĆ
bouring modules.

Interlinking blocks are available in various housing designs
and with alternative connections:

Type of plug conĆ

t

Number

f i

Interlinking block in

nector

of pins

plastic
version

metal
version

M18

4−pin

·

ć

7/8"

4−pin

·

ć

5−pin

·

·

Push pull

5−pin

ć

·

· Available
ć Not available

Interlinking blocks with 5−pin plug connectors enable separĆ
ate electrical circuits for the operating voltage for electronics/
sensors and the load voltage for outputs/valves.