2. Assembly

2−7

Festo P.BE−CPX−SYS−EN en 0902e

2.2.1

Replacing a complete module or interlinking block with tie rod interĆ
linking

The interlinking blocks in the plastic version are connected to
each other mechanically by means of two tie rods. The tie
rods are situated in a groove in the housing open at the rear.

1

Tie rod groove

2

Tie rod

1

2

Fig. 2/1:

CPX terminal with tie rod interlinking (rear view)

Dismantling

Proceed as follows in order to remove a complete module or a
interlinking block:

1. Dismantle the CPX terminal

2. Unscrew and remove completely the tie rod screws in the

left−hand end plate (see Fig. 2/2). The interlinking blocks
are now held together only by the electrical plug conĆ
nectors.