10

Lochinvar 2" installation (Fig.14)
1. Slide PolyPro pipe w/ PVC adapter into

oblong hole and down. Brackets will
point away from the wall, on the exterior
of the house, and rest between the two
outward beads.

2. Install the termination assembly

in accordance with appliance
manufacturer’s instructions.

3. Verify exhaust pipe cannot be removed

from termination cap.

Figure 15

POLYPRO PIPE

W/PVC ADAPTER

(SUPPLIED WITH

TERMINATION KIT)

Figure 14

BRACKET

POLYPRO PIPE

W/PVC ADAPTER

(SUPPLIED WITH

TERMINATION KIT)

Figure 13

SCREW TO

TERMINATION

AIR INTAKE

EXHAUST

CO-LINEAR

ADAPTER

INSTALL

GASKETS

EXTERIOR

WALL PLATE

INTERIOR

WALL PLATE

HORIZONTAL

TERMINATION

7. Slide exhaust tip into exhaust pipe.
8. Mount outer cover plate to exterior wall

plate.

9. install Poly Pro venting system to/from

termination to appliance.

Horizontal Concentric (Fig.13)
1. Locate penetration.
2. Cut hole. (Table 3)
3. Attach and seal exterior exterior wall

plate onto outside wall.

4. Slide cap through exterior wall plate into

hole from outside building. Cap must

not be installed sloped downward.

5. Orient termination so air intake slots

face down.

6. Seal termination to exterior wall plate

with silicone sealant.

7. Slide interior wall plate over termination

and attach to wall from inside the room.

8. Attach interior wall plate to termination

with provided hardware.

9. Install gaskets into Co-Linear Adapter.
10. Attach Co-Linear Adapter to Horizontal

Termination.

11. Install Poly Pro venting system to/from

termination to appliance.

Lochinvar 3" & 4" installation (Fig.15)
1. Slide PolyPro Pipe w/ PVC adapter into

small hole of retaining plate until it stops
on the adapter collar.

2. Finish installing the termination

assembly in accordance with appliance
manufacturer’s instructions. PolyPro