Figure 21 – DuraVent PolyPro User Manual

Page 12

Advertising
background image

12

8. Install gaskets into Co-Linear Adapter (if

applicable). (Fig.13)

9. Connect Co-Linear Adapter to

termination (if applicable). (Fig.19)

10. Install Poly Pro venting system to/from

Co-Linear Adapter or termination to
appliance.

BLACK

UV PROTECTED PIPE

RUBBER FLASHING

Figure 20- Vertical Pipe Termination

max length rectangle, 4 vent runs max per
support. The listing requires clearance holes
no larger than 5 1/8" Dia, with spacing 1 3/4"
apart.

The upper support plate (with a flange for
B vent and factory built chimney, Fig.22)
must be affixed to the top of the conduit via
screws. Anchor bolts must be used when
attaching a flat support plate to the top of
Masonry or other chase (not shown). Support
plate must be weather tight. The SS Hanger
Bracket is installed under the Gasket Plate
and affixed to the top of the support plate
with screws (Fig.22). Use non-hardening
sealant as required.

The lower portion of the vent system must
be supported and firestopped as detailed
earlier in these and/or the PP Flex instructions
(provided separately).

RIGID BLACK

UV PROTECTED

POLYPRO

GASKET

PLATE

STAINLESS

RELINE

HANGER

BRACKET

POLYPRO

FLEX LINER

RIGID

POLYPRO

STAINLESS

UPPER

SUPPORT

PLATE

GASKET PLATE

/ HANGER

MOUNT

HARDWARE

FLANGE

BIRD GUARD

Figure 21

CLEARANCE

HOLE

1.75" MAT'L

SPACE MIN

Vertical single pipe (Fig.20)
1. Follow instructions for Vertical Concentric

Termination.

2. Attach flashing to roof. (Fig.20)

Rubber boot flashing or similar,
ensure an effective, leak-proof seal
is maintained.

Use BLACK UV protected pipe.

3. Maintain 12 in. (305mm) min. clearance

above highest anticipated snow level,
max 24 in. (610mm) above roof.

MULTIPLE VENTS IN ONE CONDUIT (Fig.21)
Multiple PolyPro Rigid/Flex vent systems may
be installed within one conduit. Listed 2"-4"
M&G components must be used, and the
conduit (if pre-existing) must be inspected
and deemed sound.

Upper supports may be field supplied and
listed, the listing requires: Min thickness of 24
ga (0.020") SS, no larger than 18" Dia or 18"