DuraVent PolyPro User Manual

Page 13

Advertising
background image

13

M&G DURAVENT

POLYPRO

CHIMNEY CAP

TERMINATION

COMBUSTION

AIR INTAKE-

FLEX HANGER

BRACKET AND

HARDWARE

AIR INTAKE

FLEX

FLEX CLAMP

M&G DURAVENT

POLYPRO

EXHAUST SYSTEM

STORM COLLAR

ENCLOSURE

M&G DURAVENT

POLYPRO

EXHAUST SYSTEM

AIR INTAKE

FLEX

AIR INTAKE

FLEX TO

POLYPRO

ADAPTER

POLYPRO PIPE TO

APPLIANCE AIR

INTAKE

ALUM FLEX AIR INTAKE (Fig.23)
Important: This section only applies to
sourcing combustion air!

Reference Fig.23 for installation of air intake
flex when used with the M&G DuraVent
Chimney Cap Termination. Combustion air
is drawn in under the storm collar. Ensure
Aluminum flex is approx 1"-2" below
termination base for unrestricted operation.
See Fig.24 for the lower install.

MAINTENANCE
Have your venting system checked annually.
This can be done easily by the same
technician who inspects & services the
appliance. Recommended areas to inspect
are as follows:
- Check areas of the Venting System which
are exposed to the elements for wear or
damage. If damage is found, the components
should be replaced immediately.
- Where possible, look into the Termination
Cap to verify no foreign material is there to
block the vent. Remove any foreign material
found.
- Where practical, inspect joints to verify
that no Pipe Sections or Fittings have been
disturbed, and consequently loosened. Also
check mechanical supports such as Wall
Straps, support plates, etc for rigidity.

Figure 23- Upper Assy

Figure 24- Lower Assy

Figure 22

HANGER

MOUNTED

TO TOP OF

SUPPORT,

BELOW

GASKET

PLATE

SEAL AS

REQ'D

Advertising