Table 3 - wall & ceiling penetration sizing table – DuraVent PolyPro User Manual

Page 9

Advertising
background image

9

7. Add additional components to raise vent

level if desired (vent to be 12" above
grade or average snow level).

8. Remove gasket and install Bird Guard

into end of pipe. (Fig.11)

9. Install Poly Pro venting system to/from

termination to appliance.

Figure 12

POSITIONED

HORIZONTALLY

POSITIONED

VERTICALLY

AIR INLET PIPE

OUTER COVER PLATE

APPLY BEAD OF SILICON SEALANT

AROUND FEMALE END OF PIPE TO

SEAL AGAINST EXTERIOR WALL PLATE

INTERIOR

WALL PLATE

EXTERIOR WALL PLATE

EXHAUST TIP

EXHAUST PIPE

Table 3 - Wall & Ceiling Penetration Sizing Table

VENT DIAMETER

Termination

2"

3"

4"

5"

6"

8"

CONCENTRIC
VERTICAL OR HORIZONTAL

4 1⁄8"

105mm

5 1⁄8"

130mm

6 1⁄8"

155mm

N/A

N/A

N/A

TWIN PIPE HORIZONTAL
CLASS IIB

7 3⁄8" x 25⁄8"

187mm x

65mm

8 3⁄8" x 37⁄8"

212 x 85mm

9" x 43⁄8"

228 x 100mm

N/A

N/A

N/A

TWIN PIPE HORIZONTAL
CLASS IIC (Framing Dimensions)

8" x 3"

200 x 77mm

8 7⁄8" x 37⁄8"

225 x 98mm

9 3⁄8" x 4 3⁄8"

238 x 112mm

N/A

N/A

N/A

SINGLE HORIZONTAL

CLASS IIB

25⁄8"

65mm /

3 3⁄8" "

85mm

4" "

100mm

N/A

N/A

N/A

SINGLE HORIZONTAL
CLASS IIC (Framing Dimensions)

3"

77mm

3 7⁄8

98mm

4 3⁄8

112mm

N/A

N/A

N/A

SINGLE WALL W/ LOCKING BAND
VERTICAL

3 1⁄2"

4 1⁄4"

5 1⁄8"

6 1⁄2"

7 1⁄4"

9 1⁄4"

SINGLE PIPE NO LOCKING BANDS
VERTICAL

3"

3 3⁄4"

4 1⁄2"

5 3⁄4"

6 3⁄4"

7 3⁄4"

Horizontal Twin Pipe (Fig.12)
1. Locate penetration.
2. Cut or cut and frame hole. (Table 3)
3. Attach interior wall plate to inside wall.
4. Attach and seal exterior wall plate to

outside wall.

5. Slide pipes through outer plate.
6. Rotate pipes to slide pipe past keyway.