3 Specifications

10

WIKA operating instructions digital indicator DI30

Case

Material

Aluminium, black

Ingress protection

Front: IP 54, Rear: IP 00

Dimensions

96 x 96 x76 mm (w x h x d) including terminals

Mounting clearance

horizontal 120 mm / vertical 120 mm
(recommended)

Weight

Approx. 530 g

Mounting

sliding fasteners, fixed via screws, for panel
thicknesses from 1 mm to 10 mm

{Wall mounting
enclosure}

Material

ABS, black, cable gland

Ingress protection

IP 65

Dimensions

160 x 130 x 60 mm (w x h x d)

Cable gland

Cable thickness: 4.0...8.0 mm

Mounting

Fixing holes for screws

Permissible ambient conditions

Operating temperature

0…60 °C

Storage temperature

-20…80 °C

Humidity

0…75 % relative humidity, non-condensing

CE conformity

EMC directive

2004/108/EC, EN 61326-1 Emission (Group 1,
Class B) and Immunity (industrial locations)

Low voltage directive

2006/95/EC, EN 61010-1


{ } Items in curved brackets are optional extras for additional price.

For further specifications see WIKA data sheet AC 80.05 and the order
documentation.