4.4 CALLIBRATION PROCESS

The Vision II Pro

TM

has been calibrated at the

factory. However, it is recommended that you
verify calibration before using your headlight aimer
for the first time and on a monthly basis. There are
three things that get calibrated during this process
(1) Internal Digital Level (2) Vehicle Miss-
Alignment Sensor (3) Vehicle Centerline Laser. To
get started, from the Main Menu select the Options
button (5) then select the CAL button (4).

STEP 1

Using a 5/32” T-Handle or Allen wrench loosen the
set screw on the wheel cam. Adjust the cam until
the vertical bubble vial on the top of the aim head
is level, then tighten set screw.

STEP 2

Locate the calibration marks located on the back
of the LCD screen and rotate the bezel until the 2
marks are perfectly aligned as shown.

STEP 3

Rotate the laser knob on the side of the bezel and
verify the laser dot hits the 2 calibration targets on
the top of the aimer case as shown. If adjustment
is needed, you can adjust the set screws on the
side of the laser knob until the dot hits both
calibration targets.

Front Laser Target