Table 1. example volume settings, 3 volume limits, Cs3318 – Cirrus Logic CS3318 User Manual

Page 20

Advertising
background image

20

DS693F1

CS3318

Table 1

shows example volume settings using individual and master volume controls.

Refer to

Figure 6 on page 18

for a graphical representation of the volume controls’ functionality.

5.5.3

Volume Limits

The analog section of the CS3318 is designed to accommodate gain and attenuation over the range of
+22 dB to -96 dB. Values outside this range may, however, be written to the CS3318’s internal registers.
As shown in

Figure 6 on page 18

, the value of the Individual and Master volume control registers are

summed before being limited to the range allowed by the CS3318’s analog section. This architecture has
the benefit of allowing both individual and master volume control input beyond the analog range of the
CS3318.

If the effective volume (See

Equation 1 on page 19

) of an individual channel is greater than +22 dB, the

channel’s volume will be set to +22 dB.

If the effective volume of an individual channel is less than -96 dB, the channel will mute, but the MuteChX
bit will not be set. When the channel’s effective volume returns to -96 dB or above, the mute condition will
be released. It should be noted that if the channel’s MuteChX bit or any of the channel’s unmasked
Master X Mute bits are set, the channel will remain muted until the necessary mute conditions are re-
leased.

Individual

ChX

Master 1

Mask 1

ChX

Master 2

Mask 2

ChX

Master 3

Mask 3

ChX

Level

ChX

Channel 1

+3.75 dB

+1.0 dB

0

+5.25 dB

0

-8.5 dB

0

+3.75 dB

Channel 2

+2.5 dB

0

0

1

-6.0 dB

Channel 3

+1.25 dB

0

1

0

+6.5 dB

Channel 4

0 dB

0

1

1

-3.25 dB

Channel 5

-1.25 dB

1

0

0

-0.25 dB

Channel 6

-2.5 dB

1

0

1

-10.0 dB

Channel 7

-3.75 dB

1

1

0

+2.5 dB

Channel 8

-4.0 dB

1

1

1

-6.25 dB

Table 1. Example Volume Settings

Referenced Control

Register Location

Master X Volume.................

“Master 1 Volume - Address 11h” on page 36
“Master 2 Volume - Address 14h” on page 37
“Master 3 Volume - Address 17h” on page 38

Master X Control .................

“Master 1 Control - Address 12h” on page 37
“Master 2 Control - Address 15h” on page 38
“Master 3 Control - Address 18h” on page 39

Master X Mask ....................

“Master 1 Mask - Address 10h” on page 36
“Master 2 Mask - Address 13h” on page 37
“Master 3 Mask - Address 16h” on page 38

Referenced Control

Register Location

MuteChX .............................

“Mute Control - Address 0Ah” on page 33

Master X Mute.....................

“Master 1 Mute (Bit 1)” on page 37
“Master 2 Mute (Bit 1)” on page 38
“Master 3 Mute (Bit 1)” on page 39

Advertising