2. CHARACTERISTICS AND SPECIFICATIONS

RECOMMENDED OPERATING CONDITIONS

GND = 0 V; all voltages with respect to ground.

(Note 1)

Notes: 1.

Device functional operation is guaranteed within these limits. Functionality is not guaranteed or implied
outside of these limits. Operation outside of these limits may adversely affect device reliability.

ABSOLUTE MAXIMUM RATINGS

GND = 0 V; all voltages with respect to ground.

WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation

is not guaranteed at these extremes.

Notes: 2.

The maximum over/under voltage is limited by the input current except on the power supply pin.

Parameters

Symbol Min Typ

Max

Units

DC power supply

Analog power

Interface power

VA
VL

4.75

1.4

5.0

1.8, 3.3, 5.0

5.25
5.25

V
V

Ambient operating temperature (power applied)

-CSZ

T

A

-40

-

+85

°C

Parameters

Symbol

Min

Max

Units

DC power supply

Low voltage analog power

Interface power

VA
VL

-0.3
-0.3

6.0
6.0

V
V

Input current, any pin except supplies

I

in

-

±10

mA

Digital input voltage

(Note 2)

Digital interface

V

IN-L

-0.3

VL+ 0.4

V

Ambient operating temperature (power applied)

T

A

-55

+125

°C

Storage temperature

T

stg

-65

+150

°C