7.8.6

Mute Polarity and Detect (MUTEP1:0)

Default = 00
00 - Auto polarity detect, selected from MUTEC1 pin
01 - Reserved
10 - Active low mute polarity
11 - Active high mute polarity

Function:

Auto mute polarity detect (00)

See

Section 4.11 “The MUTEC Outputs” on page 30

for description.

Active low mute polarity (10)

When RST is low, the outputs are high impedance and will need to be biased active. Once reset has been
released and after this bit is set, the MUTEC output pins will be active low polarity.

Active high mute polarity (11)

At reset time, the outputs are high impedance and will need to be biased active. Once reset has been
released and after this bit is set, the MUTEC output pins will be active high polarity.

7.9

Mute Control (Address 09h)

7.9.1

Mute (MUTE_xx)

Default = 0
0 - Disabled
1 - Enabled

Function:

The Digital-to-Analog converter output will mute when enabled. The quiescent voltage on the output will
be retained. The muting function is affected, similarly to attenuation changes, by the Soft and Zero Cross
bits. The MUTE pins will go active during the mute period according to the MUTEC bit.

7

6

5

4

3

2

1

0

MUTE_B4

MUTE_A4

MUTE_B3

MUTE_A3

MUTE_B2

MUTE_A2

MUTE_B1

MUTE_A1

0

0

0

0

0

0

0

0