Digital inputs, 1 tdata connection, 2 mclk connection – Cirrus Logic CS4373A User Manual

Page 22: 3 msync connection, Figure 11. digital inputs, Cs4373a, For mea

Advertising
background image

CS4373A

22

DS699F2

6. DIGITAL INPUTS

The CS4373A is designed to operate with the
CS5376A digital filter. The digital filter gener-
ates one-bit

∆Σ test bit stream data (TDATA),

a master clock (MCLK) and a synchronization
signal (MSYNC). In addition, the digital filter
GPIO pins control the CS4373A operational
mode (MODE) and attenuator (ATT) settings.

6.1 TDATA Connection

The TDATA digital input expects encoded
one-bit

∆Σ data nominally at a 256 kHz rate.

The one’s density input range is approximately
25% minimum to 75% maximum, with differen-
tial mid-scale at 50% one’s density.

The CS5376A digital filter test bit stream
(TBS) generator can encode two types of AC
signals as over-sampled, one-bit

∆Σ data - a

pure sine wave for THD and CMRR testing or
a triggerable impulse waveform for synchroni-
zation testing and impulse response charac-
terization. In the AC operational modes, the
CS4373A converts the over-sampled bit
stream digital data into precision differential or
common mode analog AC signals.

The CS5376A TBS sine mode encodes an ap-
proximately 5 V

pp

full-scale sine wave signal

with a digital filter TBSGAIN register setting of
0x04B8F2. Because TBS impulse mode en-
codes frequencies above 100 Hz, a maximum
0x0078E5 TBSGAIN impulse mode register
setting is specified to guarantee stability of the

CS4373A low-power

∆Σ circuitry. Details on

the setup and operation of the digital filter TBS
generator can be found in the CS5376A data
sheet.

6.2 MCLK Connection

The CS5376A digital filter generates the mas-
ter clock for CS4373A, typically 2.048 MHz,
from a synchronous CLK input from the exter-
nal system. By default, MCLK is disabled at re-
set and is enabled by writing the digital filter
CONFIG register. If MCLK is disabled during
operation, the CS4373A will enter power down
after approximately 40

µ

S.

MCLK must have low in-band jitter to guaran-
tee full analog performance, requiring a crys-
tal- or VCXO-based system clock into the
digital filter. Clock jitter on the digital filter ex-
ternal CLK input directly translates to jitter on
MCLK.

6.3 MSYNC Connection

The CS5376A digital filter also provides a syn-
chronization signal to the CS4373A. The
MSYNC signal is generated following a rising
edge received on the digital filter SYNC input.
By default MSYNC generation is disabled at
reset and is enabled by writing to the digital fil-
ter CONFIG register.

The input SYNC signal to the CS5376A digital
filter sets a common reference time t

0

for mea-

CS4373A

TDATA

CAP+

CAP-

BUF+

BUF-

OUT+

OUT-

MCLK

MSYNC

DGND

MODE1
MODE2

ATT0
ATT1

MODE0

ATT2

VA-

2.5 V

VREF

10

VREF+

VREF-

100µF

VA+

VA-

VD

0.1µF

0.1µF

VD

VA+

10nF

C0G

Analog

Switches

CH1 BUF

CH2 BUF

CH3 BUF

CH4 BUF

CH1,2,3,4 OUT

SWITCH

CONTROL

GPIO

CS5376A
SIGNALS

MCLK
MSYNC

TBSDATA

GPIO

GPIO

GPIO

GPIO

GPIO

ELECTRONICS

SENSOR

VA-

0.1µF

VA-

+

Route VREF as diff pair

Route OUT as diff pair

Route BUF as diff pair

Figure 11. Digital Inputs