Ac differential modes 1, 2, 3, Cs4373a – Cirrus Logic CS4373A User Manual

Page 7

Advertising
background image

CS4373A

DS699F2

7

AC DIFFERENTIAL MODES 1, 2, 3

Notes: 10. Maximum amplitude for operation above 100 Hz. A reduced amplitude for higher frequencies is required

to guarantee stability of the low-power delta-sigma architecture.

11. Full-scale accuracy compares the defined full-scale 1/1 amplitude to the measured 1/1 amplitude.

Specification is for unloaded outputs. Applying a differential load lowers the output amplitude ratiometric
to the differential output impedance.

12. Relative accuracy compares the measured 1/2,1/4,1/8,1/16,1/32,1/64 amplitude to the measured 1/1

amplitude.

13. Common mode voltage is defined as [(SIG+) + (SIG-)] / 2.

14. Specification is for the parameter over the specified temperature range and is for the device only. It does

not include the effects of external components.

Parameter

Symbol Min Typ

Max

Unit

AC Differential Characteristics

Full-scale Differential AC Output

1/1
1/2
1/4
1/8

1/16
1/32
1/64

VAC

FS

-
-
-
-
-
-
-

5

2.5

1.25

625

312.5

156.25
78.125

-
-
-
-
-
-
-

V

pp

V

pp

V

pp

mV

pp

mV

pp

mV

pp

mV

pp

Full-scale Bandwidth

(

Note 8)

VAC

BW

-

-

100

Hz

Impulse Amplitude

(

Note 8, 10

)

VAC

IMP

-

-

-20

dBfs

AC Differential Accuracy

Full-scale Accuracy

1/1

(

Note 3

,

11

)

VAC

ABS

- 0.5

- 0.2

0.2

%FS

Relative Accuracy

1/2

(

Note 12

)

1/4
1/8

1/16
1/32
1/64

VAC

REL

- 0.2

-
-
-
-
-

± 0.1
± 0.1
± 0.1

- 0.1 ± 0.2
- 0.2 ± 0.3
- 0.5 ± 0.5

0.2

-
-
-
-
-

%
%
%
%
%
%

Full-scale Drift

(

Note 14

)

VAC

TC

-

25

-

µV/°C

DC Common Mode Characteristics

Common Mode

(

Note 13)

VAC

CM

-

(VA-)+2.35

-

V

Common Mode Drift

(

Note 13

,

14

)

VAC

CMTC

-

300

-

µV/°C

Advertising