Switching characteristics, Figure 4. mosi write timing in spi slave mode, Figure 5. miso read timing in spi slave mode – Cirrus Logic CS5378 User Manual

Page 14: Cs5378

Advertising
background image

CS5378

DS639F3

14

SWITCHING CHARACTERISTICS

Serial Configuration Interface Timing (External Master)

Parameter

Symbol Min Typ

Max

Unit

MOSI Write Timing
SS:EECS Enable to Valid Latch Clock

t

1

60

-

-

ns

Data Set-up Time Prior to SCK Rising

t

2

60

-

-

ns

Data Hold Time After SCK Rising

t

3

120

-

-

ns

SCK High Time

t

4

120

-

-

ns

SCK Low Time

t

5

120

-

-

ns

SCK Falling Prior to SS:EECS Disable

t

6

60

-

-

ns

MISO Read Timing
SCK Falling to New Data Bit

t

7

-

-

60

ns

SCK High Time

t

8

120

-

-

ns

SCK Low Time

t

9

120

-

-

ns

SS:EECS Rising to MISO Hi-Z

t

10

-

-

150

ns

Figure 4. MOSI Write Timing in SPI Slave Mode

SSI

MOSI

SCLK

MSB

MSB - 1

LSB

t

6

t

5

t

4

t

3

t

2

t

1

SCK

SS:EECS

Figure 5. MISO Read Timing in SPI Slave Mode

MISO

SCLK

MSB

MSB - 1

LSB

t

10

t

9

t

8

t

7

SSI

SS:EECS

SCK

Advertising