6. PLL AND CLOCK GENERATION

The CS5378 requires a 32.768 MHz master clock,
which can be supplied directly or from an internal
phase locked loop. This master clock is used to
generate an internal digital filter clock and an exter-
nal modulator clock.

The internal PLL will lock to standard clock or
Manchester encoded input signals. The input type
and input frequency are selected by the reset state
of the PLL mode select pins.

6.1 Pin Descriptions

CLK - Pin 17

Clock or PLL input, standard clock or Manchester.

GPIO[4:6]:PLL[0:2] - Pins 5, 6, 7

PLL mode select, latched immediately after reset.
Weak (~100 k

Ω) internal pull-ups default high, ex-

ternal 10 k

Ω pull-downs required to set low.

6.2 PLL Mode Select

The CS5378 PLL operational mode and frequency
are selected immediately after reset based on the
state of the PLL[0:2] pins. On the rising edge of the
reset signal, the digital high or low state of the
PLL[0:2] pins is latched and used to program the
clock input type and frequency.

A weak internal pull-up resistor (~100 k

Ω) will

hold the PLL mode select pins high by default. To
force the pin low on reset, an external 10 k

Ω pull-

down resistor should be connected. Once the pin
state is latched following reset, the GPIO[4:6] pins
function without affecting PLL operation.

6.3 Synchronous Clocking

To guarantee synchronous measurements through-
out a sensor network, a system clock should be dis-
tributed to arrive at all nodes in phase. The
distributed system clock can either be the full
32.768 MHz master clock, or the CS5378 PLL can
create a synchronous 32.768 MHz clock from a
slower clock. To ensure the generated clock re-
mains synchronous with the network, the CS5378
PLL uses a phase/frequency detector architecture.

PLL

CLK

DSPCFG Register

MCLK

Internal
Clocks

Figure 12. Clock Generation Block Diagram

Clock Divider

Generator

and MCLK

Output

PLL[2:0]

32.768

MHz

PLL[2:0]

PLL Mode

111

32.768 MHz clock input (PLL bypass).

110

1.024 MHz clock input.

101

2.048 MHz clock input.

100

4.096 MHz clock input.

011

32.768 MHz clock input (PLL bypass).

010

1.024 MHz Manchester input.

001

2.048 MHz Manchester input.

000

4.096 MHz Manchester input.

Table 5. PLL Mode Selections