Cs5480 – Cirrus Logic CS5480 User Manual

Page 46

Advertising
background image

CS5480

46

DS980F3

6.6.13 Interrupt Status (Status0) – Page 0, Address 23

Default = 0x80 0000

The Status0 register indicates a variety of conditions within the chip.

Writing a one to a Status0 register bit will clear that bit. Writing a ‘0’ to any bit has no effect.

DRDY

Data Ready.
During conversion, this bit indicates that low-rate results have been updated.
It indicates completion of other host instruction and the reset sequence.

CRDY

Conversion Ready.
Indicates that sample rate (output word rate) results have been updated.

WOF

Watchdog timer overflow.

[20:19]

Reserved.

MIPS

MIPS overflow.
Sets when the calculation engine has not completed processing a sample before the
next one arrives.

V2SWELL (V1SWELL) V2 (V1) swell event detected.
P2OR (P1OR)

Power out of range.
Sets when the measured power would cause the P2 (P1) register to overflow.

I2OR (I1OR)

Power out of range.
Sets when the measured current would cause the I2 (I1) register to overflow.

V2OR (V1OR)

Voltage out of range.
Sets when the measured current would cause the V2 (V1) register to overflow.

I2OC (I1OC)

I2 (I1) overcurrent.

V2SAG (V1SAG)

V2 (V1) sag event detected.

TUP

Temperature updated.
Indicates when the Temperature register (T) has been updated.

FUP

Frequency updated.
Indicates the Epsilon register has been updated.

IC

Invalid command has been received.

RX_CSUM_ERR

Received data checksum error.
Sets to ‘1’ automatically if checksum error is detected on serial port received data.

[1]

Reserved.

RX_TO

SDI/RX time out.
Sets to ‘1’ automatically when SDI/RX time out occurs.

23

22

21

20

19

18

17

16

DRDY

CRDY

WOF

-

-

MIPS

V2SWELL

V1SWELL

15

14

13

12

11

10

9

8

P2OR

P1OR

I2OR

I1OR

V2OR

V1OR

I2OC

I1OC

7

6

5

4

3

2

1

0

V2SAG

V1SAG

TUP

FUP

IC

RX_CSUM_ERR

-

RX_TO