CS5480

DS980F3

65

6) If the phase offset is negative, then the delay should

be added only to the current channel. Otherwise,
add more delay to the voltage channel than to the
current channel to compensate for a positive phase
offset.

Once the phase offset is known, the CPCCx and FPCCx
bits for that channel are calculated and programmed in
the PC register.
CPCCx bits are used if either:
• The phase offset is more than 1 output word rate

(OWR) sample.

• More delay is needed on the voltage channel.
The compensation resolution is 0.008789° at 50Hz and
0.010547° at 60Hz at an OWR of 4000Hz.

7.3 Temperature Sensor Calibration

Temperature sensor calibration involves the adjustment
of two parameters: temperature gain (T

GAIN

) and

temperature offset (T

OFF

). Before calibration, T

GAIN

must be set to 1.0 (0x 01 0000), and T

OFF

must be set

to 0.0 (0x 00 0000).

7.3.1 Temperature Offset and Gain Calibration

To obtain the optimal temperature offset (T

OFF

) register

value and temperature (T

GAIN

) register value, it is

necessary to measure the temperature (T) register at a
minimum of two points (T1 and T2) across the meter
operating temperature range. The two temperature
points must be far enough apart to yield reasonable
accuracy, for example 25

°

C and 85

°

C. Obtain a linear

fit of these points (

), where the slope (m)

and intercept (b) can be obtained.

Figure 26. T Register vs. Force Temp

T

OFF

and T

GAIN

are calculated using the following

equations:

y

m x b

+

=

F

or

ce T

e

m

p

er

at

ur

e (

°

C)

T Register Value

Y = m • x + b

m

b

T1

T2

TOFF

b

m

-----

=

TGAIN

m

=