8. BASIC APPLICATION CIRCUITS

Figure 27 shows the CS5480 configured to measure
power in a single-phase, 3-wire system with 1 voltage
and 2 currents (1V-2I).

Figure 28

shows the CS5480

configured to measure power in a single-phase, 2-wire

system with 1 voltage, 1 line current and 1 neutral
current (1V-1I-1N). In these diagrams, current
transformers (CTs) are used to sense the line load
currents, and resistive voltage dividers are used to
sense the line voltage.

CT

CT

5 x 330K

CS5480

27nF

27nF

1K

1K

L1

L2

N

IIN1+

IIN1-

IIN2+

IIN2-

Application

Processor

RESET

RX

TX

GNDA GNDD

DO3

DO1

DO2

VDDA

+3.3V

0.1µF

0.1µF

+3.3V

VDDD

+3.3V

VREF-

VREF+

0.1

µ

F

27nF

27nF

1K

1K

½ R

BURDEN

Wh

Varh

4.096MHz

XIN

XOUT

SSEL

Interrupt

½ R

BURDEN

½ R

BURDEN

½ R

BURDEN

MODE

VIN+

VIN-

27nF

27nF

1K

1K

+3.3V

LOA D

LOA D

0.1

µ

F

10K

+3.3V

CS

1 Voltage and 2 Current

Figure 27. Typical Single-phase 3-Wire Connection