Characteristics and specifications, Recommended operating conditions, Power measurement characteristics – Cirrus Logic CS5480 User Manual

Page 9: Typical load performance, Figure 4. active energy load performance, Cs5480

Advertising
background image

CS5480

DS980F3

9

3. CHARACTERISTICS AND SPECIFICATIONS

RECOMMENDED OPERATING CONDITIONS

POWER MEASUREMENT CHARACTERISTICS

Notes: 1. Specifications guaranteed by design and characterization.

2. Active energy is tested with power factor (PF) = 1.0. Reactive energy is tested with Sin(

) = 1.0. Energy error measured at system

level using a single energy pulse. Where: 1) One energy pulse = 0.5Wh or 0.5Varh; 2) VDDA = +3.3V, T

A

= 25°C, MCLK =

4.096MHz; 3) System is calibrated.

3. Calculated using register values; N

4000.

4. I

RMS

error calculated using register values. 1) VDDA = +3.3V; T

A

= 25°C; MCLK = 4.096MHz; 2) AC offset calibration applied.

TYPICAL LOAD PERFORMANCE

• Energy error measured at system level using single energy pulse; where one energy pulse = 0.5Wh or 0.5Varh.
• I

RMS

error calculated using register values.

• VDDA = +3.3V; T

A

= 25°C; MCLK = 4.096MHz.

Parameter

Symbol Min Typ

Max

Unit

Positive Analog Power Supply

VDDA

3.0

3.3

3.6

V

Specified Temperature Range

T

A

-40

-

+85

°C

Parameter

Symbol Min Typ

Max

Unit

Active Energy

All Gain Ranges

(Note 1 and 2)

Current Channel Input Signal Dynamic Range 4000:1

P

Avg

-

±0.1

-

%

Reactive Energy

All Gain Ranges

(Note 1 and 2)

Current Channel Input Signal Dynamic Range 4000:1

Q

Avg

-

±0.1

-

%

Apparent Power

All Gain Ranges

(Note 1 and 3)

Current Channel Input Signal Dynamic Range 1000:1

S

-

±0.1

-

%

Current RMS

All Gain Ranges

(Note 1, 3, and 4)

Current Channel Input Signal Dynamic Range 1000:1

I

RMS

-

±0.1

-

%

Voltage RMS

(Note 1 and 3)

Voltage Channel Input Signal Dynamic Range 20:1

V

RMS

-

±0.1

-

%

Power Factor

All Gain Ranges

(Note 1 and 3)

Current Channel Input Signal Dynamic Range 1000:1

PF

-

±0.1

-

%

-1

-0.5

0

0.5

1

0

500

1000

1500

2000

2500

3000

3500

4000

4500

Perce

nt Erro

r (%)

Current Dynamic Range (x : 1

)

Lagging PF = 0.5

Leading PF = 0.5

PF = 1

Figure 4. Active Energy Load Performance

Advertising