Crd5490-z – Cirrus Logic CRD5490 User Manual

Page 21

Advertising
background image

CRD5490-Z

DS988RD1

21

8. Confirm the load has been removed or turned off, and then click Yes from the CONFIRM LOAD window shown in

Figure 23.

9. The offset register value automatically updates when the calibration is completed (approximately 5 seconds).

The AC Offset register value should change.

Figure 23. Calibration Tab with CONFIRM LOAD Window

Figure 24. AC Offset Register Updated After AC Offset Calibration