Hardware overview, Crd5490-z, Warning – Cirrus Logic CRD5490 User Manual

Page 4: High voltage hazard

Advertising
background image

CRD5490-Z

4

DS988RD1

2. HARDWARE OVERVIEW

The CRD5490-Z includes sensors (line voltage and current shunt), a power supply, a CS5490 power
monitor calculation engine, isolation, and an MCU. Figure 1 shows connections of each block.

Make sure that the power source is off before wiring any connection. The AC source is connected to plug IEC 60320
C14, and the AC load is connected to connector IEC 60320 C13. Make sure that all connectors are well connected
before the power source is turned on. Make sure all AC power line wiring is secured to the box and away from contact
before the power source is on.

WARNING

High Voltage Hazard

When the CRD5490-Z is connected to AC lines, high voltage is present inside the box.

Do not remove the protective cover from the CRD5490-Z when power is connected.

The evaluation board connects directly to the AC power line and presents a serious risk of

electric shock and can cause serious injury or death. Extreme caution needs to be

exercised while handling this box. Make sure that the power source is off before wiring any

connection. Make sure that all connectors are well connected before the power source is

turned on. Make sure all AC power line wiring is secured to the box and away from contact

before the power source is on.

Refer to additional warnings at the beginning of this document.

AC

Load

Current

Sensor

Voltage

Divide Sensor

+3.3V

Voltage

Input

Current Input

MCU

USB

Cap. Drop

+ Buck Supply

Is

o

la

tio

n

CS5490

CRD5490-Z

RX

RESET

TX

Figure 1. System Block Diagram

Advertising