1. CHARACTERISTICS AND SPECIFICATIONS
1.1 Recommended Operating Conditions
1.2 Electrical Characteristics
Parameter
Symbol Min Typ
Max
Unit
Reference
Line Voltage
V
AC
90
-
260
V
Load Current
I
RMS
-
-
15
A
Peak Current
I
PEAK
-
-
22
A
Fundamental Frequency
Freq
5
-
2000
Hz
Ambient Operating Temperature
T
A
-40
85
C
Parameter
Symbol Min Typ
Max
Unit
Reference
Power Consumption (V
AC
= 240V, 50Hz)
P
AC
-
0.6
-
W
Accuracy (PF=1, Sample Count 8000 - 2 second, Temp Compensation Enabled)
RMS Voltage (90-260V
AC
)
V
RMS
-
0.1
-
%
RMS Current (15mA-15A)
I
RMS
-
0.1
-
%
Active Power (1.5W-3900W)
P
AVG
-
0.1
-
%