F64c/h oil removal (coalescing) filters, Ale-2-11 typical performance characteristics, Service kits – Norgren Filter Contents User Manual

Page 35: Technical data

Advertising
background image

F64C/H Oil Removal (Coalescing) Filters

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

ALE-2-11

Typical Performance Characteristics

Inlet Pressure

Maximum Flow†

F64C

F64H

psig

(bar)

scfm

(dm

3

/s)

scfm

(dm

3

/s)

15

(1)

14

(6.4)

24

(11.2)

45

(3)

23

(11.0)

41

(19.3)

70

(5)

30

(14.3)

53

(24.9)

90

(6.3)

34

(16.0)

59

(28.0)

100

(7)

36

(16.9)

63

(29.5)

130

(9)

40

(19.1)

71

(33.5)

† Maximum flow to maintain stated oil removal performance.

Service Kits

Item

Type

Part Number

Service kit

F64C/H

4380-200

Service kit (pre-filter)

F64G

4380-200

Element F64G (pre-filter)

5 µm

4338-01

Element F64C

Coalescing

4344-01

Element F64H

Coalescing

4344-02

Replacement sight glass

Prismatic (standard)

4380-040

Pyrex

4380-041

Replacement drains

Automatic

3000-97

Manual

684-84

Service kit includes port seals, louver o-ring, bowl o-ring and drain gasket.

4.13 (105)†

1.46

(37)

2.91

(74)

F64C, Automatic Drain

9.40 (239)

††

1.46

(37)

6.45 (164)

2.32 (59)

7.05 (179)

F64C, 1/4 Turn Manual Drain

10.00 (254)

††

† 6.18" (157) for 3/4" ports.
†† Minimum clearance required to remove unit.

11.57 (294)

††

8.58 (218)

F64H, Automatic Drain

F64H, 1/4 Turn Manual Drain

12.20 (310)

††

9.21 (234)

Service
Indicator

Technical Data

Fluid: Compressed air
Maximum pressure: 250 psig (17 bar)
Operating temperature*: 0° to +150°F (-20° to +65°C)

* Air supply must be dry enough to avoid ice formation at temperatures below +35°F (+2°C).

Particle removal: 0.01 µm
Air quality: Within ISO 8573-1, Class 1 (particulates) and Class 2 (oil content).

Maximum remaining oil content: 0.01 mg/m3 at +70°F (+20°C) with an inlet

concentration of 17 mg/m3.

Maximum flow at 90 psig (6.3 bar) inlet pressure to maintain stated oil removal

performance:

1/2" ports: 74 scfm (35 dm3/s)

3/4" ports: 74 scfm (35 dm3/s)

1" ports: 127 scfm (60 dm3/s)

1/4 turn manual drain connection: 1/8" pipe thread
Automatic drain connection: 1/8" pipe thread
Automatic drain operating conditions (float operated):

Bowl pressure required to close drain: Greater than 5 psig (0.3 bar)
Bowl pressure required to open drain: Less than 3 psig (0.2 bar)
Minimum air flow required to close drain: 2 scfm (1 dm3/s)
Manual operation: Depress pin inside drain outlet to drain bowl

Nominal bowl size:

1 pint U.S. (0.5 liter)
1 quart U.S. (1 liter)

Materials:

Body: Aluminum
Yoke: Aluminum
Bowl: Aluminum
Liquid level indicator: Pyrex
Element: Synthetic fibre and polyurethane foam
Elastomers: Synthetic rubber
Service life indicator:

Body: Transparent nylon
Internal parts: Acetal
Spring: Stainless steel
Elastomers Nitrile

An automatic drain is a two-way valve, which will close when the system is

pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.

Advertising