B64g filter/regulators, Ale-12-11, Iso symbols – Norgren Filter/Regulators User Manual

Page 11: Technical data, Typical performance characteristics, Service kits

Advertising
background image

B64G Filter/Regulators

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

ALE-12-11

All Dimensions in Inches (mm)

ISO Symbols

Automatic Drain

Relieving

Manual Drain

Relieving

Automatic Drain

Non Relieving

Manual Drain

Non Relieving

Technical Data

Fluid: Compressed air
Maximum pressure

Guarded transparent bowl: 150 psig (10 bar)
Metal bowl: 250 psig (17 bar)

Operating temperature*

Guarded transparent bowl: -30° to 125°F (-34° to 50°C)
Metal bowl: -30° to 175°F (-34° to 80°C)

* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).

Particle removal: 5, 25 or 40 µm. Within ISO 8573-1, Class 3 and Class 5
Typical flow at 90 psig (6.3 bar) inlet pressure:

225 scfm (106 dm

3

/s)

Manual drain connection: Will fit 1/8-27 and 1/8-28 pipe thread
Automatic drain connection: Will fit 1/8-27 and 1/8-28 pipe thread
Automatic drain operating conditions:

Minimum pressure: 10 psig (0.7 bar).
Drain opens when bowl pressure drops below 3 psig (0.2 bar).
Minimum air flow: 2 scfm (1 dm

3

/s) required to close drain.

Gauge Ports:

1/8" PTF with PTF main ports
1/8" ISO Rc with ISO Rc main ports
1/8" ISO Rc with ISO G main ports

Nominal bowl size:

7 fluid ounce (0.2 liter)

Materials:

Body: Zinc
Bonnet: Aluminum
Valve: Brass
Yoke: Zinc
Metal bowl: Aluminum
Standard metal bowl prismatic liquid level indicator lens: Grilamid
Optional metal bowl sight glass: Pyrex
Optional transparent bowl: Polycarbonate
Element: Sintered plastic
Elastomers: Synthetic rubber

An automatic drain is a two-way valve, which will close when the system is

pressurized. The drain opens when the float rises due to accumulated liquid
and on depressurization.

Typical Performance Characteristics

FLOW CHARACTERISTICS

0 20 40 60 80 100

dm

3

/s

AIR FLOW

0 40 80 120

160

200

240

scfm

OUTLET PRESSURE

8

6

4

2

0

bar g

100

80

60

40

20

0

psig

PORT SIZE: 1/2"

40

µ

m ELEMENT

INLET PRESSURE: 150 psig (10 bar)
RANGE: 5 to 150 psig (0.3 to 10 bar)

Service Kits

Item

Type

Part Number

Service kit

Relieving

4383-200

Non relieving

4383-201

5 µm

4338-01

Replacement elements

25 µm

4338-99

40 µm

4338-02

Replacement Sight Glass

Prismatic (standard) 4380-040
Pyrex

4380-041

Replacement Drains

Automatic

3000-10

Manual

684-84

Service kit includes diaphragm assembly, valve assembly,

valve spring, louver o-ring, bowl o-ring, drain seal.

** 4.13 (105) for 1/4", 3/8", and 1/2" ported yokes.

6.18" (157) for 3/4" ported yokes.

† Add 1.46 (37) for units with T-handle adjustment.
†† Minimum clearance required to remove unit.

Add 1.46 (37) for units with T-handle adjustment.

4.92 (125)

11.30 (287)

11.99 (303)

††

12.60 (320)

††

11.97 (304)

4.13 (105)**

1.46

(37)

2.91 (74)

Advertising