1.3 INTERNATIONAL ELECTRICAL SPECIFICATIONS
The table below shows the electrical requirements per barrel. Refer to the tables in Section 1.2 for the remainder of
the specifi cations. There is a separate electrical circuit for each barrel.
Air Cooled Remote
Water Cooled
Electrical
1 Phase, 200-220
VAC, 50Hz
3 Phase, 380-415*
VAC, 50Hz
1 Phase, 200-220
VAC, 50Hz
3 Phase, 380-415*
VAC, 50Hz
circuit ampacity
(per barrel)
12A minimum
6A minimum
32A minimum
12A minimum
overcurrent protection
device (per barrel)
25A maximum
10A maximum
50A maximum
20A maximum
Hopper Condensing
Unit
1 Phase, 200-240 VAC, 50Hz
Requires a 15amp power cord
Drive Motor
Three - 2 hp
* The 380-415 VAC supply requires a neutral. The power supply must be 5 wire for proper operation.
Remote Condensing Unit (1 per barrel)
Electrical
1 Phase, 200-220 VAC, 50Hz 3 Phase, 380-415 VAC, 50Hz
circuit ampacity
20A minimum
15A minimum
overcurrent protection
device
25A maximum
20A maximum
Refrigerant
R-404A
Charge
20 lbs. (Charged at Factory)