Vollrath CC404A-Water Cooled User Manual
Page 9
![background image](/manuals/468487/9/background.png)
Owner’s Manual #513642
3
CC Model Machines
CC404A
Dimensions
Machine
with crate
width
42-1/2’’ (108,0 cm)
50’’ (127,0 cm)
height
61-7/8’’ (157,2 cm)
67’’ (170,2 cm)
depth
47-1/8’’ (119,7 cm)
60’’ (152,4 cm)
Weight
1135 lbs (514,8 kg)
1210 lbs (548,8 kg)
Electrical
3 Phase, 208-240 VAC, 60Hz
circuit ampacity
(per barrel)
9A minimum
overcurrent protection
device (per barrel)
15A maximum
Hopper Condensing
Unit
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Drive Motor
Four - 3 hp
Cooling
Air cooled units require one remote
condensing unit (with compressor) per
barrel. Condensing units #285092 and
#285093 ship from the factory with 20 lbs
of R-404A for up to a 50’ line set. Add 1
lb of refrigerant for every 10’ increase to
the line set. Line set max 100’. (Remote
condensers CU-0010 and CU-0020 do
not ship charged and require 24 lbs of
R-404A)
Water cooled units are self contained and
require a Standard Hose Adapter water
fi tting and a 1/2” OD drain fi tting for each
barrel. They are charged with R-404A.
Maximum water pressure of 130 psi
Minimum water fl ow rate of 3 GPM
Ideal EWT of 60°-80°F
Hopper Volume
Four - 8.8 gallon (33,32 liters)
Remote Condensing Unit (1 per barrel)
Dimensions
Condenser
width
37-3/4’’ (95,9 cm)
height
17-1/4’’ (43,7 cm)
depth
28-1/4’’ (71,7 cm)
Weight
222 lbs (100,7 kg)
Electrical
1 Phase, 208-230 VAC, 60Hz 3 Phase, 208-230 VAC, 60Hz
circuit ampacity
20A minimum
15A minimum
overcurrent protection
device
25A maximum
20A maximum
Refrigerant
R-404A
Charge
20 lbs. (Charged at Factory)
Refrigerated Line
Sizes
Liquid Line - 3/8”
Suction Line - 7/8”