CC Model Machines

B.

Freezing Cylinder Off/On

The Freezing Cylinder OFF/ON switch is a two
position toggle switch used to supply power to the
freezing cylinder control circuit. When the switch
is in the OFF position, the freezing cylinder’s
refrigeration system and auger will not operate.
When the switch is in the ON position, the freezing
cylinder will be operational.

C.

Product Selector Switch

The product selector switch changes the
refrigeration profi le of the right freezing cylinder
to allow two different products to be made. Before
the machine is in ready mode, this switch can be
moved to the desired profi le.

D.

Hopper Off Light

A

fl ashing light indicates the Hopper Refi rgeration

Switch is in the OFF position; no refrigeration is
being supplied to the hopper. Place the Hopper
Refrigeration switch in the ON position for hopper
refrigeration..

E.

PUSH TO FREEZE Button

The PUSH TO FREEZE button is used to initiate
the run mode. To start the machine, place the
Freezing Cylinder OFF-ON switch in the ON
position and press the PUSH TO FREEZE button.

F. LEDs

The membrane switch features two lights; a green
LED and an amber LED. The green LED will fl ash
when the freezing cylinder is near ready mode
and stay lit during ready mode. The amber LED
is lit during standby, purge and clean modes.

NOTE

If the machine enters an error condition, alternat-
ing green and amber lights will fl ash. The LCD will
display an error. Turn the Freezing Cylinder OFF-
ON switch to the OFF position, correct the problem
(Refer to Troubleshooting in Section 4) and turn the
machine back on.

G. PURGE/CLEAN

Button

PURGE Mode - When the PURGE/CLEAN
button is pressed, the auger will rotate. A PURGE
message will display on the screen along with a
5 minute timer. Hopper refrigeration will continue
to run. When the timer gets to 0:00 and no other
buttons are pressed, the machine will go into
standby mode.

CLEAN Mode - During PURGE mode, if the
PURGE/CLEAN button is pressed and held for 3
seconds, the CLEAN mode will begin. The auger
will continue to rotate and hopper refrigeration will
stop.

H.

Mix Low Light Indicator

The MIX LOW message will appear on the
LCD display to alert the operator to a low mix
condition. The message will display when there is
approximately one gallon of mix left in the hopper.
When the MIX LOW message is displayed, refi ll
hopper immediately.

NOTE

Failure to refi ll hopper immediately may result in
operational problems.

I.

Menu Navigation Buttons

The Menu Navigation Buttons are primarily used
for machine calibration.

Selection Button (SEL) The SEL button is not
functional in the normal operation mode. This
button is only used by service technicians for
machine calibration.

Set Button (SET) The SET button is not functional
in the normal operation mode. This button is
only used by service technicians for machine
calibration.

Left Arrow Button (

) Pressing any button on

the control panel will automatically illuminate the
display. The backlight will turn off several seconds
after use. To keep the display constantly lit, press
and hold the left (

) button for fi ve seconds. The

backlight function can be reset to normal operation
in the same manner.

Up Arrow Button (

) The

button is not

functional in the normal operation mode. This
button is only used by service technicians for
machine calibration.

Figure 3-2 IntelliTec Control

Push to Freeze

Green LED

Amber LED

SEL Button

SET Button

Purge/Clean
Button

Up Arrow Button

Left Arrow Button