Vollrath CC404A-Water Cooled User Manual
Page 8
![background image](/manuals/468487/8/background.png)
Owner’s Manual #513642
2
CC Model Machines
1.2 SPECIFICATIONS
CC202A Air Cooled Remote
CC202A Water Cooled
Dimensions
Machine
with crate
Machine
with crate
width
25-1/2’’ (64,8 cm)
44-1/2’’ (113,0 cm)
25-1/2’’ (64,8 cm)
44-1/2’’ (113,0 cm)
height
61-7/8’’ (157,2 cm)
67’’ (170,2 cm)
61-7/8’’ (157,2 cm)
67’’ (170,2 cm)
depth
47-1/8’’ (119,7 cm)
60’’ (152,4 cm)
47-1/8’’ (119,7 cm)
60’’ (152,4 cm)
Weight
632 lbs (286,6 kg)
707 lbs (320,6 kg)
930 lbs (421,8 kg)
1005 lbs (455,8 kg)
Electrical
1 Phase, 208-240
VAC, 60Hz
3 Phase, 208-240
VAC, 60Hz
1 Phase, 208-240
VAC, 60Hz
3 Phase, 208-240
VAC, 60Hz
circuit ampacity
(per barrel)
12A minimum
9A minimum
29A minimum
19A minimum
overcurrent protection
device (per barrel)
25A maximum
15A maximum
50A maximum
30A maximum
Hopper Condensing
Unit
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Drive Motor
Two - 3 hp
Cooling
Air cooled units require one remote
condensing unit (with compressor) per
barrel. Condensing units #285092 and
#285093 ship from the factory with 20 lbs
of R-404A for up to a 50’ line set. Add 1
lb of refrigerant for every 10’ increase to
the line set. Line set max 100’. (Remote
condensers CU-0010 and CU-0020 do
not ship charged and require 24 lbs of
R-404A)
Water cooled units are self contained and
require a Standard Hose Adapter water
fi tting and a 1/2” OD drain fi tting for each
barrel. They are charged with R-404A.
Maximum water pressure of 130 psi
Minimum water fl ow rate of 3 GPM
Ideal EWT of 60°-80°F
Hopper Volume
Two - 8.8 gallon (33,32 liters)
CC303A Air Cooled Remote
CC303A Water Cooled
Dimensions
Machine
with crate
Machine
with crate
width
32-1/2’’ (82,6 cm)
44-1/2’’ (113,0 cm)
32-1/2’’ (82,6 cm)
44-1/2’’ (113,0 cm)
height
61-7/8’’ (157,2 cm)
67’’ (170,2 cm)
61-7/8’’ (157,2 cm)
67’’ (170,2 cm)
depth
47-1/8’’ (119,7 cm)
60’’ (152,4 cm)
47-1/8’’ (119,7 cm)
60’’ (152,4 cm)
Weight
895 lbs (405,9 kg)
970 lbs (439,9 kg)
1345 lbs (610,0 kg)
1420 lbs (644,1 kg)
Electrical
1 Phase, 208-240
VAC, 60Hz
3 Phase, 208-240
VAC, 60Hz
1 Phase, 208-240
VAC, 60Hz
3 Phase, 208-240
VAC, 60Hz
circuit ampacity
(per barrel)
12A minimum
9A minimum
29A minimum
19A minimum
overcurrent protection
device (per barrel)
25A maximum
15A maximum
50A maximum
30A maximum
Hopper Condensing
Unit
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Drive Motor
Three - 3 hp
Cooling
Air cooled units require one remote
condensing unit (with compressor) per
barrel. Condensing units #285092 and
#285093 ship from the factory with 20 lbs
of R-404A for up to a 50’ line set. Add 1
lb of refrigerant for every 10’ increase to
the line set. Line set max 100’. (Remote
condensers CU-0010 and CU-0020 do
not ship charged and require 24 lbs of
R-404A)
Water cooled units are self contained and
require a Standard Hose Adapter water
fi tting and a 1/2” OD drain fi tting for each
barrel. They are charged with R-404A.
Maximum water pressure of 130 psi
Minimum water fl ow rate of 3 GPM
Ideal EWT of 60°-80°F
Hopper Volume
Three - 8.8 gallon (33,32 liters)