Vollrath CC404A-Water Cooled User Manual
Page 24
Owner’s Manual #513642
18
CC Model Machines
E.
Lubricate the inside and outside of the front wear
bushing with Petrol Gel and install it onto the
auger (Fig. 3-7).
F.
Install the large o-ring onto the faceplate and
install the faceplate onto the machine.
G.
Install slide, hopper cover and drain tray.
3.11 ROUTINE CLEANING
To remove spilled or dried mix from the machine exterior,
wash in the direction of the fi nish with warm soapy water
and wipe dry. Do not use highly abrasive materials, as
they will mar the fi nish.
3.12 PREVENTATIVE MAINTENANCE
It is recommended that a maintenance schedule be fol-
lowed to keep the machine clean and operating properly.
A. DAILY
Disassemble and Clean
The frequency of cleaning the freezer and freezer parts
must comply with local health regulations. Refer to the
previous sections for proper disassembly and cleaning
instructions.
Lubricate Front Wearguard
Petrol Gel sanitary lubricant or equivalent must be used
when lubrication of parts is specifi ed. Apply a thin fi lm of
sanitary lubricant to the inside and outside of the front
wearguard.
Inspect Parts
Inspection for worn or broken parts should be made each
time the freezer is disassembled. All worn or broken parts
should be replaced to ensure safety to both the operator
and the customer and to maintain good freezer perfor-
mance and a quality
Lubricate Back End of the Auger
Lubricate the rear of the auger with a small amount of
spline lubricant.
B. WEEKLY
Clean Inside Of Machine
Remove all side panels and clean the inside of the ma-
chine. Wipe any custard that may have dripped onto the
inner panels with a damp soapy towel. Wash the drain tray.
C. MONTHLY
Clean Condenser Coils (And Filters If Applicable)
The coils on the hopper, dipping cabinet and remote con-
denser need to be cleaned to ensure proper airfl ow. Use
compressed air to clean the condensers. Blow the air in
the opposite direction of the normal airfl ow.
C. QUARTERLY
Replace Barrel Parts According To Schedule
Follow the Parts Replacement Schedule below to keep
the freezer operating properly.
D. ANNUALLY
WARNING
High voltage will shock, burn or cause death. Turn
off and lock out main power disconnect before
servicing. Do not operate machine with panels
removed.
Replace Barrel Parts
Follow the Parts Replacement Schedule below to keep
the freezer operating properly.
Drive Belt Wear and Tension
Inspect the drive belts for wear. Check for wear marks from
the belts rubbing on the pulley. Press fi rmly on the belts.
When tension is properly adjusted, the belt will depress
the approximate width of the belt with the pressure of a
fi nger. If you think the belt is out of tension consult the
Owner’s Manual or contact Stoelting Customer Service.
Figure 3-7 Install Front Wear Bushing
Figure 3-8 Parts Replacement Schedule
Part
Description
3 Months Annually Qty per Barrel
C-2000-50 Spring
X
12
C-2000-51 Blade
X
12
SL-0010
Seal - Beater Shaft
X
1
149014
Bushing - Front Auger Support
X
1
625174
O-Ring - Front Door
X
1