6 lamp runtime warning, Lamp runtime warning, Advanced – Barco R9010570 User Manual

Page 71

Advertising
background image

7. Advanced

A lamp failing to startup will be noticed by a low light output of the projector since the projector goes in single
lamp mode.

In case of a lamp error contact the local Barco authorized technician

How to clear the lamp error ?

1. Press MENU to activate the Tool bar

2. Press → to select the Lamp item

3. Press ↓ to Pull down the Lamp menu

4. Use ↑ or ↓ to select Clear lamp error

Image 7-54

5. Press ENTER

A dialog box will be shown to confirm the lamp error removal. Confirm.

The lamp error logo is removed from the screen

7.6.6

Lamp runtime warning

What can be done ?

When the lamp has reached a predetermined runtime , a warning message will be displayed on the screen. The lamp runtime
warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp
lifetime.

How to set the lamp runtime warning?

1. Press MENU to activate the Tool bar

2. Press → to select the Lamp item

3. Press ↓ to Pull down the Lamp menu

4. Use ↑ or ↓ to select Runtime warning

Image 7-55

5. Press ENTER

R59770079 BARCO ID H250/500 23/07/2007