System Configuration Setup
Using the Sensor Data and LCD Setup tool
108
Procedure After Removing a Redundant Power Supply and Redundant
FAN
The SMC board monitors any removal of a power supply and fan. If a
redundant power supply or redundant fan is removed, it will be detected and a
fault lamp will start blinking. To stop the fault lamp’s blinking, you must use
the Sensor Data & LCD Setup Tool to deactivate the redundant power supply
sensor or fan sensor on the SMC board. (It is re-activated automatically if an
additional power supply is installed.) Follow the procedure below:
SMC board sensor setup
1 Insert the Sensor Data & LCD Setup Tool floppy disk into the floppy disk
drive.
2 Turn on the server.
3 The following menu choices will appear:
Choose option “1. Setup SMC Board Sensor Data”
4 The program will show the current number of power supplies and fan mod-
ule.
5 Enter the new number of power supplies. The program will respond with
“OK.” To exit the program, press the <Esc> key.
1. Setup SMC Board Sensor Data
2. Setup LCD Display Message
3. Setup Expansion HDD Chassis Sensor Data
TOSHIBA SMC Configuration Program VerX.XX
*** Setup Redundant ***
PS Unit Count: 0X
FAN Unit Count: 0X
*** Redundant Setting ***
SET PS Unit Count ([1] - [4] or [Esc]) >> X OK!
SET FAN Unit Count ([1] - [2] or [Esc]) >> X OK!
*** Setup Redundant END ***
HIT ANY KEY