Toshiba Magnia 7010 User Manual

Page 26

Advertising
background image

Getting Started
Front with doors open

10

Default settings are displayed as MAGNIA 7010. You can use a tool to
change what is displayed. Refer to “Using the Sensor Data and LCD Setup
tool” on page 106.

3 Fault information

The messages that may be displayed when a malfunction occurs are listed
below.
For the FAN number and power supply number designations, see the
diagram shown below.

MAGNIA 7010

Messages

Meaning

Note

SYS FAN Failure

FAN#n on Unit#1

Failure of Standard FAN’s FAN n.

n = FAN No
(1 ... 5)

SYS FAN Failure

FAN#n on Unit#2

Failure of Redundant FAN’s FAN n.

n = FAN No
(1 ... 5)

CPU FAN Failure

CPU FAN#n

Failure of CPU FAN n.

n = FAN No
(1 ... 2)

FAN Degraded to

Non-Redundant

Failure of redundant FAN which has
become non-redundant.

Fan Unit

Degraded Non-

Redundant

The quantity of FAN units decreased and
they have become non-redundant.

SYS FAN Failure

No FAN Unit

Without FAN Unit

PS Failure Power

Supply #n

Failure of power supply n.

n = PS No
(1 ... 4)

PS Degraded to

Non-Redundant

Failure of redundant power supply which
has become non-redundant.

Excessive Number

of PS Installed

The number of power supply units is
excessive.

Insufficient #

of PS Installed

The number of power supply units is
insufficient.

DC Short in

Drive Subsystem!

DC shorted in 5" device bay HDD.

DC Short on

Motherboard!

DC shorted on system board.