Toshiba Magnia 3100 User Manual

Page 70

Advertising
background image

62

HW Diagnostics

SAF-TE TEST


[11. SAF-TE TEST]
To check the SAF-TE function and the status LED of the hard disk drives.

[01. SAF-TE test]
It detects SAF-TE controller and checks the operation by flashing the LED for each hard disk drive.
The test detects the SAF-TE controller first and shows the connecting destination of the detected
SAF-TE controller (host number, SCSI ID, and channel number) with model name.

--HT—ID----CH--VENDOR—PRODUCT-------FAN—PS--SLOT
XX XX XX XXXXX XXXX XX XX XX

After detecting the SAF-TE controller, the following message appears:

SAF-TE LED Steady ON (Faulty Flag) Hit any key

When the message above appears, check that all LEDs of the hard disk drives light in orange. Then
press <Enter> key.

SAF-TE LED Blinking (Rebuilding Flag) Hit any key

When the message above appears, check that all LEDs of the hard disk drives are flashing orange.
Then press <Enter> key.

SAF-TE LED Steady ON (Rebuild Interrupted) Hit any key

When the message above appears, check that all LEDs of the hard disk drives light in orange. Then
press <Enter> key.

SAF-TE LED Blinking (Rebuilding Flag) Hit any key

When the message above appears, check that all LEDs of the hard disk drives are flashing orange.
Then press <Enter> key.

SAF-TE LED Reset (No Error Flag) Hit any key

When the message above appears, check that all LEDs of the hard disk drives turn off. Then press
<Enter> key.


SAF-TE TEST (SAF) Error log

Status Error

name

Meaning

01

SAF-TE TEST ERROR

SAF-TE controller has not been detected.

Advertising