Philips AVENT Esterilizador a vapor digital User Manual

Page 4

Advertising
background image

7

Electronic Display Guide

Steriliser plugged in and
ready for mode selection

Ready for

Mode 1 selection

Mode 1 sterilisation

in progress –

indicated by a beep

and rotating ‘0’

Mode 2 sterilisation

in progress –

indicated by a beep

and three ascending

and descending bars

Numerical countdown indicates

sterilisation almost complete (Mode 1 only)

BEEP

BEEP

Ready for

Mode 2 selection

BEEP

BEEP

BEEP

X

5

Sterilisation complete – indicated
by 5 beeps and three flashing bars –
items will remain sterile for up to
6 hours provided the lid is not opened

Up to 6 hours sterile time remaining

Up to 4 hours sterile time remaining

Up to 2 hours sterile time remaining

BEEP

Completion of Mode 1 cycle (6 hours),
Mode 2 cycle (24 hours) – indicated by
a long beep and a flashing ‘0’

BEEP

Water level too high.
See ‘Troubleshooting’ below

Water level too low.
See ‘Troubleshooting’ below

BEEP

Steriliser will not work

Excessive steam escaping

from under the lid

Sterilising cycle takes too long

Flashing

lower

and side

bars, and beep

Flashing

top and

side bars,

and beep

Check that the mains lead is connected to the steriliser as well as plugged into the mains.

Check fuse in plug.

Parts incorrectly loaded. Refer to instructions on page 4.

The steriliser is loaded with only a few items – light loads will take longer to cycle.

Insufficient water has been placed in the steriliser. Switch off, remove water, (take care if the

steriliser body is hot) and replace with 90ml of water for use with Mode 1 OR 200ml of water

for use with Mode 2. Restart the unit.

An excessive amount of water has been placed in the steriliser. Switch off, remove water, (take

care if the steriliser body is hot) and replace with 90ml of water for use with Mode 1 OR 200ml

of water for use with Mode 2. Restart the unit.

BEEP

BEEP

Troubleshooting Guide

OR:
2. Pour 100ml vinegar mixed with 200ml cold water into the steriliser.

Allow to stand in the unit until any limescale has dissolved.

Drain and rinse the inside of the steriliser thoroughly. Wipe dry.

* Citric Acid is available from most chemists – avoid contact with eyes

as this may cause irritation. Keep out of reach of children.

WARNINGS

Ensure the steriliser is placed on a firm level surface when in use.
When in use, the steriliser contains boiling water and steam

escapes from the vent in the lid.

Never place items on top of the steriliser.
Take care when opening as steam can burn.
During the sterilising cycle the lid and the steriliser body are

very hot.

Always keep out of reach of children.
Never open the unit during the 6 minute sterilising cycle. Items

are not sterile if the 6 minute sterilising cycle is interrupted.

To completely stop the steriliser at any time during a cycle, press

and hold the control button for 2 seconds to return to selection

mode or, unplug at the mains.

Always disconnect the lead from the back of the steriliser before

pouring away water and/or rinsing.

Always unplug from the mains supply when not in use.
The power supply must be removed from the unit for it to be

completely switched off.

Never immerse the steriliser in water.
Never use the steriliser without water.
Do not use bleach or chemical sterilising solutions/tablets in your

steam steriliser or on products to be sterilised.

Do not use abrasive, anti-bacterial materials or scourers to clean

the steriliser.

Do not use softened water in the steriliser.
The lead supplied must not be used on any other appliance and no

other lead should be used with the Digital Steriliser.

Failure to follow de-scaling instructions may cause

irreparable damage.

There are no serviceable parts inside the Digital Steriliser.

Do not attempt to open, service or repair the Digital Steriliser

yourself.

CAUTION: This appliance is intended for use by responsible

persons, keep out of the reach of small children and the infirm.

This appliance is not intended for use by persons including

children with reduced physical, sensory or mental

capabilities, or lack of experience or knowledge, unless they

have been given supervision or instruction concerning use of

the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not

play with the appliance.

6

Instructions for use

The Philips AVENT Digital Steam Steriliser is one of a new generation

of intelligent products from Philips AVENT.
The Digital Steriliser uses the intensive heat of steam to eliminate

harmful bacteria helping you sterilise your baby feeding equipment

as safely and quickly as possible. There are two different modes for

greater convenience:
Mode 1 (Optional six hour mode) runs a single 6 minute sterilising

cycle, then keeps the contents sterile for 6 hours, providing the lid is

not removed.
Mode 2 keeps contents sterile for up to 24 hours by continuously

repeating the cycle, so you can have clean, sterile bottles day and night.
As well as bottles and breastfeeding accessories, you can sterilise any

other boilable items (please refer to the manufacturer’s instructions

regarding sterilisation).
Please take a few minutes to read through the ENTIRE INSTRUCTION

LEAFLET before using your Digital Steriliser for the first time. PLEASE

SAVE THESE INSTRUCTIONS. Also available at www.philips.com/AVENT

Contents

(see diagram A, page 2)

a) Lid

f) Steriliser body

b) Upper basket

g) Measuring Cup

c) Bottle rack

h) De-scaler (citric acid)

d) Lower basket (same as b)

i) Tongs

e) Central stem

j) Lead and plug

NB: Upper and lower baskets are identical

Before using your steriliser for the first time

(see diagram B and refer to the Electronic Display Guide opposite)

Remove all items from inside the steriliser body.
1. Measure exactly 90ml of water and pour in.
2. Assemble the blue components (baskets, stem and bottle rack)

and place into the steriliser. Put the lid on.

3. Connect the lead into the back of the steriliser and plug into the

mains supply.

4. The unit will display a flashing ‘0’ to indicate you need to select

a mode. One short press of the control button will display a

flashing ‘1’. Hold the control button in for 2 seconds then release,

and a rotating ‘0’ is displayed. Mode 1 is now in progress.

5. After the water has reached 100°C, it will turn to steam. When the

sterilising cycle is almost complete a numerical countdown will be

displayed (see ‘Electronic Display Guide’).

6. At the end of the cycle the unit will beep 5 times. Three bars will

flash and then remain displayed.

7. Let the steriliser cool down for 3 minutes. Unplug and disconnect

the lead from the back of the steriliser.

8. Remove the blue components and empty any remaining water

from the unit. Wipe dry. The steriliser is now ready for use.

Sterilising in Mode 1 – 6 hour sterile period
Sterilising in Mode 2 – 24 hour sterile period

(see diagram C, page 3)

To sterilise up to six 125ml, 260ml or 330ml AVENT Bottles
Before each use, wash items in mild soapy water and rinse.
1. Measure and pour in exactly 90ml of water if selecting Mode 1

OR 200ml of water if selecting Mode 2.

2. Slide the lower basket onto the central stem. Thread 2 screw rings

onto the central stem. Slide the bottle rack down the central stem,

with the neck facing down, until it rests on the top screw ring.

3. Place the teats through the centre of the holes in the bottle rack

onto the lower basket. Thread 4 screw rings onto the central stem.

4. Place inverted bottles in the bottle rack and push the upper basket

onto the central stem until it rests on the catch. Place dome caps

and tongs into the upper basket.

5. The upper basket is not required when sterilising 330ml bottles.
6. Place the assembled unit into the steriliser body and put the lid on.

Put the lead into the back of the steriliser body and plug into the

mains supply. A flashing ‘0’ will appear, indicating that you need to

select a mode.

7. To select Mode 1, press the control button once and the mode

number will be displayed. To run this mode, hold the control button

in for 2 seconds, then release. A rotating ‘0’ will be displayed.

Mode 1 is now in progress.

OR
To select Mode 2, press the control button twice and the mode

number will be displayed. To run this mode, hold the control button

in for 2 seconds, then release. Three ascending and descending bars

will be displayed. Mode 2 is now in progress.

8. Do not remove the lid until the 6 minute sterilising cycle has

ended. This is indicated by 5 beeps and 3 bars being displayed. It is

recommended to let the steriliser cool down for 3 minutes after the

sterilising cycle has been completed. Items will remain sterile for up

to 6 hours provided the lid is not removed. After 2 hours, the

display will show 2 bars and, after a further 2 hours, one bar. To

indicate the end of Mode 1 or 2, the unit will sound a long beep

followed by a flashing ‘0’†. At this point items should be used

immediately or re-sterilised. (Please refer to ‘To remove sterilised

items after a cycle’). Unplug the lead from the back of the steriliser.

Pour away any remaining water, rinse out the inside of the

steriliser body and wipe dry.

† The end of a cycle is 6 hours after commencement of Mode 1 and

24 hours after commencement of Mode 2. The unit can be completely

stopped at any time during a cycle, by pressing and holding in the

control button for 2 seconds. The unit will beep and a flashing ‘0’ will

be displayed, indicating the unit has returned to selection mode.

To load the Philips AVENT Manual Breast Pump

(see diagram D page 3)

Before each use, wash items in mild soapy water and rinse.
1. Disassemble the Breast Pump and click the pump body into

the slot in the upper basket and arrange the other breast pump

components as shown.

2. Place remaining components of the pump in the lower basket.
3. Up to six 125ml or 260ml bottles (not including screw rings,

teats or dome caps) can be sterilised with the pump.

4. Follow sterilising instructions.

To remove sterilised items after a cycle

(see diagram E page 3)

1. When Mode 1 cycle is complete pressing the button will

reset the unit.

2. In Mode 2 (after sterilised) when 3x bars are displayed,

pressing the button will pause the cycle, allowing

removal/addition of item. Pressing the button again will

resume the cycle (re-sterilise). The unit will immediately

enter a new sterilisation phase and continue the 24 hour

cycle from where it was interrupted. If unplugged the

countdown cycle will stop.

3. Wash your hands thoroughly before removing the

sterilised items.

4. Remove the lid.
5. If necessary, shake excess water from items before

assembling.

6. The tongs can be used to remove small items and to pull

the sterile teats through the screw rings of the bottles.

7. Removed items must be used/assembled immediately or

re-sterilised. Expressed milk can be stored in a sterile breast

milk container in the refrigerator for up to 48 hours (not in

the door) or in the freezer for up to 3 months. Infant

formula should be made up fresh for each feed.

8. After each cycle the unit should be allowed to cool for

at least 3 minutes before opening and removing parts.

If after a Mode 1 cycle is run the unit must be allowed

to cool for a minimum of 10 minutes prior to running

another sterilisation cycle.

Dishwasher Basket

(see diagram F page 3)

1. Two baskets can be clipped together to hold small items such as

teats, breast pump parts etc. for washing in the top rack of your

dishwasher prior to sterilisation.

2. To clip together, align the baskets so that the indicators are

opposite each other and snap the baskets together. To open,

pull apart with fingers.

Warning: Your Philips AVENT items may discolour over time if they

are washed in the dishwasher with dirty items covered with

remnants of strong sauces, such as tomato sauce.

Care of your steriliser

Using pre-boiled or filtered water in your Digital Steriliser can reduce

limescale build up. You should de-scale your steriliser every four weeks,

or as often as needed in hard water areas, to ensure it continues to

work 100% effectively. Under no circumstances should anything

other than citric acid or vinegar be used as it may cause irreparable

damage. Avoid contact with eyes as this may cause irritation. Keep

out of the reach of children.
EITHER:
1. Mix one sachet of citric acid (10gms) with 200ml of water.

Pour into the empty steriliser*. Do not put lid on. Activate Mode 1

and leave for 1-2 minutes. Unplug and leave to stand for 30

minutes. Drain and rinse the inside of the steriliser. Then in

Mode 1, run a full sterilising cycle empty with the lid on, using

exactly 90ml of water. Drain and wipe dry.