TABLE 8—MODEL 350MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

850

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

875

43

3.5

43

3.6

43

3.7

43

3.8

42

3.2

900

44

3.7

43

3.4

43

3.5

43

3.6

43

3.7

0

925

44

3.5

44

3.7

44

3.8

43

3.4

43

3.5

950

44

3.4

44

3.5

44

3.6

44

3.7

44

3.8

to

975

44

3.2

44

3.3

44

3.4

44

3.5

44

3.6

1000

45

3.7

45

3.8

44

3.2

44

3.4

44

3.5

2000

1025

45

3.5

45

3.6

45

3.7

44

3.2

44

3.3

1050

45

3.3

45

3.4

45

3.6

45

3.7

45

3.8

1075

45

3.2

45

3.3

45

3.4

45

3.5

45

3.6

1100

47

3.6

47

3.7

45

3.2

45

3.4

45

3.5

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

and

Canada

U.S.A.

775

43

3.8

42

3.2

42

3.3

42

3.4

42

3.5

Altitudes

800

43

3.5

43

3.7

43

3.8

42

3.2

42

3.3

2001

825

44

3.8

43

3.4

43

3.6

43

3.7

43

3.8

to

850

44

3.6

44

3.7

44

3.8

43

3.5

43

3.6

3000

875

44

3.4

44

3.5

44

3.6

44

3.7

43

3.4

or

900

44

3.2

44

3.3

44

3.4

44

3.5

44

3.6

Canada

925

45

3.7

45

3.8

44

3.2

44

3.3

44

3.4

Altitudes

950

45

3.5

45

3.6

45

3.7

45

3.8

44

3.3

2000

975

45

3.3

45

3.4

45

3.5

45

3.6

45

3.8

to

1000

45

3.1

45

3.2

45

3.4

45

3.5

45

3.6

4500

1025

45

3.0

45

3.1

45

3.2

45

3.3

45

3.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

750

43

3.7

43

3.8

42

3.3

42

3.4

42

3.5

775

43

3.5

43

3.6

43

3.7

43

3.8

42

3.2

800

44

3.7

43

3.4

43

3.5

43

3.6

43

3.7

3001

825

44

3.5

44

3.6

44

3.8

43

3.4

43

3.5

850

44

3.3

44

3.4

44

3.5

44

3.7

44

3.8

to

875

45

3.8

44

3.2

44

3.3

44

3.5

44

3.6

900

45

3.6

45

3.7

45

3.8

44

3.3

44

3.4

4000

925

45

3.4

45

3.5

45

3.6

45

3.7

44

3.2

950

45

3.2

45

3.3

45

3.4

45

3.5

45

3.7

975

45

3.0

45

3.2

45

3.3

45

3.4

45

3.5

1000

45

2.9

45

3.0

45

3.1

45

3.2

45

3.3

—35—